     Install Location for the PIR Detector

1).Make sure the detector covers all the areas which should be covered.
2).The recommended installation height should be around 2.1M, depending on the     area to be covered.
3).To improve the detection accuracy, the detector should be kept away from heat sources, light sources, and direct sunlight through the window. The IR detector is activated by detecting an energy difference between the IR light of a moving object and that of a background object. To obtain the maximum accuracy, please focus the detector on the spot with the lowest temperature within the covered area. (Please refer to Figure 6 for installation)

    Wireless detectors test:
    Put out door sensor ,PIR detector ,smoke detector,Gas detector and so on,allof the wireless detectors ,First ,Put the batterys to the detector (change batter,Use the same type battery please).and trigger the sensor or detector ,and the alarm host will stuy the wireless signal.
    Smoke detector Work, testing and maintenance :

     The detector in working condition, its light-emitting diode LED lights approximately every minute will shine once. When smoke particles are detected, The detector will issue a sonorous voice alarm pulse. LED blinking, and the output signal alarm, until fresh air to re-up.

     Press the test button detector, the detector and alarm should have the same reaction. Smoke detector is injected into the cavity detection, the detector can also test whether the normal state.